Evaluation for each team includes: Presentation (P), Prediction Accuracy of the seismic model design (A), and Additional Material weight (M).
-
Presentation (P): To encourage participants' knowledge exchange and elaboration for design and prediction, referees will evaluate contents of the presentation given in the IDEERS Conference. Scoring “P” will be made between 0.9 and 1.
-
Additional Material weight (M): This is evaluated by the equation below:
Remarks:
-
M T : weight of the upper part of the retrofitted model (weight of the structure above the ground floor plate); M B : weight of the upper part of the benchmark model.
-
The weight of components mounted on the upper part of the retrofitted model can be deducted from the total weight M T . (Components should be replaceable. For those can not be replaced, they are not regarded as components.)
-
Any materials between the ground floor plate and the baseboard are not weighted into the equation above.
I B |
800 |
850 |
900 |
950 |
1000 |
1050 |
1100 |
1150 |
1200 |
A |
4 |
3 |
2 |
1.5 |
1 |
1.25 |
1.5 |
1.75 |
2 |
S = P * A * M
Champion will be given to the team whose value of S is the “lowest”.
|
|
|
|